Filter Results By:

Products

Applications

Manufacturers

Showing results: 46 - 51 of 51 items found.

  • Single Phase Reference Standard Meter

    Signals & Systems India Private Limited

    The Single Phase Portable Reference Standard (SPRS-1102) from SANDS is a portable meter test equipment that helps to calibrate the error present in the single-phase energy meter i.e. the meter under test (MUT). The SPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, phase angle etc of the meter under test. It has an LCD display and an alphanumeric keypad to suit the user. It can be interfaced with the PC for analysis. It has the capability of storing 1000 test results.

  • Materials And Chemical Analysis

    Anderson Materials Evaluation, Inc.

    Materials characterization, failure analysis, quality control, and materials and process development services are offered.  Our analytical techniques allow us to assess elemental and chemical material composition, thermal properties, coating thickness, electrochemical properties, surface chemistry, surface wetting, corrosion rates and pitting potentials, contamination and degradation problems, metallography, fractography, phase transitions, static coefficient of friction, adhesive bonding strength and causes of adhesive bonding failures, surface tension and surface energy, tensile and compressive strength, bend deflection, lapshear strength, elasticity properties, UV and visible light absorption and reflection, density and porosity, and many other material properties integral to improving your products.

  • Pulsed IV-Curve Solutions

    ESDEMC Technology LLC

    Pulsed IV-Curve Test and Analysis System is our new development for 2015. It is an advanced and compact pulsed IV-curve characterization system designed to simulate pulsed ESD events such as TLP, vf-TLP, HMM, HBM, EFT, and LV-Surge. It will monitor the transient voltage and current waveform during the pulse in ps or ns segment, and test the pre- and post-pulse status (leakage current, breakdown voltage, biasing current, static IV curve, etc) of the device under test (DUT), such as protection devices, semiconductors, circuit modules, touch panel sensor, etc.

  • Three Phase Reference Standard Meter

    Signals & Systems India Private Limited

    The Three Phase Reference Standard Meter (TPRS-1107) is portable equipment from SANDS. The main objective of this device is to calibrate the errors in three-phase and single-phase energy meters i.e. the meter under test (MUT). The TPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, power factor etc of the meter under test. It has an LCD display, an alphanumeric keypad that makes it easy for the user to operate the TPRS. It can be interfaced with the PC for data analysis. It has the capability of storing up to 8000 test results.

  • Static Design Verification

    ALINT-PRO - Aldec, Inc.

    ALINT-PRO™ is a design verification solution for RTL code written in VHDL, Verilog, and SystemVerilog, which is focused on verifying coding style and naming conventions, RTL and post-synthesis simulation mismatches, smooth and optimal synthesis, correct FSM descriptions, avoiding problems on further design stages, clocks and reset tree issues, CDC, RDC, DFT, and coding for portability and reuse. The solution performs static analysis based on RTL and SDC™ source files uncovering critical design issues early in the design cycle, which in turn reduces design signoff time dramatically. Running ALINT-PRO before the RTL simulation and logic synthesis phases prevents design issues spreading into the downstream stages of design flow and reduces the number of iterations required to finish the design.

  • Nanogravimetric Measuring Instrument

    EUREKA - BioAge s.r.l.

    Eureka is a QCM / EQCM (Quartz Crystal Microbalance) nanogravimetric measuring instrument capable of mass measurements in the order of nano-grams and pico-grams. Eureka can be used with gas and liquids, the cells are made by BioAge and sold with the instrument. The tool is the most versatile among those existing on the market, with an excellent quality / price ratio. It is a portable instrument as it is powered only by the PC USB port. The instrument is extremely compact, light, reliable and designed according to the current state of microelectronics. To use Eureka simply connect it to a PC USB port and install the capture software, running in Windows ™ environment,which turns out to be very simple to use, so you can do the first experiments in a very short time. For liquid measurements Eureka is an electrochemical system, therefore, electrochemical and nanogravimetric measurements can be performed at the same time (EQCM). Eureka, if connected to a self-powered portable PC, allows to perform measurements and experiments in total freedom in environments where grid voltage is not available,or experiments that are carried out in large areas in total freedom of movement. Measurements can be made on liquids, thanks to the static cell or the flow cell, or BioAge is able to design and create customized cells according to the needs of the user, varying volumes, dimensions and materials. The instrument is very versatile because the frequency measurement range can range from 0 to 50MHz, depending on the quartz crystal used. or use a gas cell designed for gas phase analysis, BioAge is able to design and produce customized cells according to the user's needs, varying volumes, dimensions and materials.The instrument is very versatile because the frequency measurement range can range from 0 to 50MHz, depending on the quartz crystal used. or use a gas cell designed for gas phase analysis, BioAge is able to design and produce customized cells according to the user's needs, varying volumes, dimensions and materials. The instrument is very versatile because the frequency measurement range can range from 0 to 50MHz, depending on the quartz crystal used.

Get Help